{"product_id":"fluke-393-fc-solar-clamp-meter-with-iflex-cat-iii-1500v-true-rms","title":"Fluke 393 FC Solar Clamp Meter with iFlex CAT III 1500V True-RMS","description":"\u003cp\u003eThe Fluke 393 FC is a True-RMS solar clamp meter for photovoltaic installation, maintenance, and other high-voltage DC work. It measures up to 1500 V DC, 1000 V AC, and 999.9 A AC\/DC through the clamp jaw, while the included iFlex flexible current probe extends AC current measurement to 2500 A.\u003c\/p\u003e\n\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCAT III 1500 V \/ CAT IV 600 V safety rating for solar PV and high-voltage DC environments\u003c\/li\u003e\n  \u003cli\u003eMeasures 1500 V DC, 1000 V AC, and 999.9 A AC\/DC through the clamp jaw\u003c\/li\u003e\n  \u003cli\u003eIncluded iFlex 18 inch flexible current probe expands AC current measurement up to 2500 A\u003c\/li\u003e\n  \u003cli\u003eThin 34 mm jaw helps access crowded combiner boxes and cable runs\u003c\/li\u003e\n  \u003cli\u003eDC power measurement displays readings in kVA\u003c\/li\u003e\n  \u003cli\u003eAudio polarity indicator helps prevent accidental miswires\u003c\/li\u003e\n  \u003cli\u003eVisual continuity indicator supports work in dark or noisy environments\u003c\/li\u003e\n  \u003cli\u003eFluke Connect support for logging and reporting test results\u003c\/li\u003e\n  \u003cli\u003eDual backlit display, inrush\/peak current, min\/max\/average, display hold, auto hold, and data logging functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eSpec\u003c\/h5\u003e\n\u003cp\u003eOfficial specifications are from the Fluke 393 FC Solar Clamp Meter CAT III 1500 V product page and Fluke 393 FC data sheet.\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC current via jaw\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(2% + 5 digits), 10 Hz to 100 Hz;\u003cbr\u003e+\/-(2.5% + 5 digits), 100 Hz to 500 Hz\u003c\/td\u003e\n\u003ctd\u003eCrest factor 2.5 at 600.0 A; 3.0 at 500.0 A; 1.42 at 999.9 A; add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC current via iFlex flexible current probe\u003c\/td\u003e\n\u003ctd\u003e999.9 A;\u003cbr\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A \u0026lt;=999.9 A;\u003cbr\u003e1 A \u0026lt;=2500 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(3% RD + 5 digits), 10 Hz to 500 Hz\u003c\/td\u003e\n\u003ctd\u003eCrest factor 2.5 at 1400 A; 3.0 at 1100 A; 1.42 at 2500 A; add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(2% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eUse ZERO function to compensate for offsets\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V;\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V \u0026lt;=600.0 V;\u003cbr\u003e1 V \u0026lt;=1000 V\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% RD + 5 digits), 20 Hz to 500 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V;\u003cbr\u003e1500 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V \u0026lt;=600.0 V;\u003cbr\u003e1 V \u0026lt;=1500 V\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003emV dc\u003c\/td\u003e\n\u003ctd\u003e500.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency via jaw\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e+\/-(0.5% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eTrigger level: 5 Hz to 10 Hz \u0026gt;=10 A; 10 Hz to 100 Hz \u0026gt;=5 A; 100 Hz to 500 Hz \u0026gt;=10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency via flexible current probe\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e+\/-(0.5% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eTrigger level: 5 Hz to 20 Hz \u0026gt;=25 A; 20 Hz to 100 Hz \u0026gt;=20 A; 100 Hz to 500 Hz \u0026gt;=25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage frequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e+\/-(0.5% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eTrigger level: 5 Hz to 20 Hz \u0026gt;=5 V; 20 Hz to 100 Hz \u0026gt;=5 V; 100 Hz to 500 Hz \u0026gt;=10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC power\u003c\/td\u003e\n\u003ctd\u003e600.0 kVA at 600.0 V dc range;\u003cbr\u003e1500 kVA at 1500 V dc range\u003c\/td\u003e\n\u003ctd\u003e0.1 kVA;\u003cbr\u003e1 kVA\u003c\/td\u003e\n\u003ctd\u003e+\/-(2% RD + 2.0 kVA);\u003cbr\u003e+\/-(2% RD + 20 kVA)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e600.0 Ohms;\u003cbr\u003e6000 Ohms;\u003cbr\u003e60.00 kOhms\u003c\/td\u003e\n\u003ctd\u003e0.1 Ohm \u0026lt;=600.0 Ohms;\u003cbr\u003e1 Ohm \u0026lt;=6000 Ohms;\u003cbr\u003e0.01 kOhm \u0026lt;=60.00 kOhms\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e100.0 uF;\u003cbr\u003e1000 uF\u003c\/td\u003e\n\u003ctd\u003e0.1 uF \u0026lt;=100.0 uF;\u003cbr\u003e1 uF \u0026lt;=1000 uF\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% RD + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInrush trigger level\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eiFlex position\u003c\/th\u003e\n\u003cth\u003ei2500-10 Flex distance\u003c\/th\u003e\n\u003cth\u003ei2500-18 Flex distance\u003c\/th\u003e\n\u003cth\u003eError\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e+\/-1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e+\/-2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage between any terminal and earth ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC; 1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic power off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-condensing below 10 deg C; \u0026lt;=90% RH at 10 deg C to 30 deg C; \u0026lt;=75% RH at 30 deg C to 40 deg C; \u0026lt;=45% RH at 40 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \/ storage altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m operating; 12000 m storage\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e281 mm x 84 mm x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e520 g with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1703 g from local package data\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible current probe diameter \/ cable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 mm diameter; 1.8 m cable length from head to electronics connector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 Pollution Degree 2; IEC 61010-2-032 CAT III 1500 V \/ CAT IV 600 V; IEC 61010-2-033 CAT III 1500 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1 portable electromagnetic environment; IEC 61326-2-2; CISPR 11 Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio frequency certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC ID: T68-FBLE; IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWireless radio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2400 MHz to 2483.5 MHz; output power \u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePV array and solar installation commissioning\u003c\/li\u003e\n  \u003cli\u003eHigh-voltage DC troubleshooting for solar, wind, battery bank, railway, and data center systems\u003c\/li\u003e\n  \u003cli\u003eCombiner box current and voltage checks where jaw access is limited\u003c\/li\u003e\n  \u003cli\u003eDC power verification with kVA display\u003c\/li\u003e\n  \u003cli\u003eLogging and sharing field measurements through Fluke Connect workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIncluded\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFluke 393 FC CAT III 1500 V TRMS clamp meter\u003c\/li\u003e\n  \u003cli\u003eCAT III 1500 V rated test leads with right-angle plugs and safety caps\u003c\/li\u003e\n  \u003cli\u003eiFlex 18 inch flexible current probe\u003c\/li\u003e\n  \u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n  \u003cli\u003ePremium carrying case\u003c\/li\u003e\n  \u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eManual\u003c\/h5\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.fluke.com\/5a587b1d-1fa4-4161-a427-b10800c1bde1_original%20file.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFluke 393 \/ 393 FC Operators Manual\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.fluke.com\/a28f2ce2-deaf-4ca1-bda6-b1060075f0ff_original%20file.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFluke 393 FC Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Fluke","offers":[{"title":"Default Title","offer_id":46149445058756,"sku":"STINF-CM-10001","price":564.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/2636\/8196\/files\/fluke-393-fc-solar-clamp-meter-front.jpg?v=1778803767","url":"https:\/\/testinglab.shop\/products\/fluke-393-fc-solar-clamp-meter-with-iflex-cat-iii-1500v-true-rms","provider":"TestingLab.shop","version":"1.0","type":"link"}