{"product_id":"fluke-376","title":"Fluke 376 FC True-RMS AC\/DC Clamp Meter with iFlex 1000V 1000A Inrush","description":"\u003cp\u003eThe Fluke 376 FC clamp meter is a professional True-RMS AC\/DC meter for electrical troubleshooting, industrial maintenance, and motor drive work. It combines 1000 A jaw measurement, iFlex flexible current probe expansion to 2500 A AC, VFD low-pass filtering, inrush measurement, and Fluke Connect wireless workflow support in one rugged field meter.\u003c\/p\u003e\n\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMeasures AC and DC current through the jaw up to 999.9 A\u003c\/li\u003e\n  \u003cli\u003eIncludes iFlex flexible current probe for AC current measurements up to 2500 A\u003c\/li\u003e\n  \u003cli\u003eMeasures AC\/DC voltage, DC millivolts, resistance, frequency, capacitance, continuity, and inrush current\u003c\/li\u003e\n  \u003cli\u003eVFD low-pass filter improves measurements on variable frequency drives\u003c\/li\u003e\n  \u003cli\u003eTrue-RMS performance for accurate non-linear signal measurement\u003c\/li\u003e\n  \u003cli\u003eFluke Connect support for wireless viewing, logging, and reporting\u003c\/li\u003e\n  \u003cli\u003eBacklit display, min\/max\/average capture, display hold, and DC zero functions\u003c\/li\u003e\n  \u003cli\u003eCAT III 1000 V \/ CAT IV 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eSpec\u003c\/h5\u003e\n\u003cp\u003eOfficial specifications are from the Fluke 370 FC Series technical data sheet for the 376 FC model.\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC current via jaw\u003c\/td\u003e\n\u003ctd\u003e376 FC: 999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(2% + 5 digits), 10 Hz to 100 Hz\u003c\/td\u003e\n\u003ctd\u003eCrest factor 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; add 2% for crest factor \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC current via iFlex flexible current probe\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A \u0026lt;=999.9 A;\u003cbr\u003e1 A \u0026lt;=2500 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(3% + 5 digits), 5 Hz to 500 Hz\u003c\/td\u003e\n\u003ctd\u003eCrest factor 3.0 at 1100 A; 2.5 at 1400 A; 1.42 at 2500 A; add 2% for crest factor \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e376 FC: 999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e+\/-(2% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V \u0026lt;=600.0 V;\u003cbr\u003e1 V \u0026lt;=1000 V\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% + 5 digits), 20 Hz to 500 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V \u0026lt;=600.0 V;\u003cbr\u003e1 V \u0026lt;=1000 V\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003emV dc\u003c\/td\u003e\n\u003ctd\u003e500.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency via jaw\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e+\/-(0.5% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eTrigger level: 5 Hz to 10 Hz \u0026gt;=10 A; 10 Hz to 100 Hz \u0026gt;=5 A; 100 Hz to 500 Hz \u0026gt;=10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency via flexible current probe\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e+\/-(0.5% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003eTrigger level: 5 Hz to 20 Hz \u0026gt;=25 A; 20 Hz to 100 Hz \u0026gt;=20 A; 100 Hz to 500 Hz \u0026gt;=25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60 kOhms\u003c\/td\u003e\n\u003ctd\u003e0.1 Ohm \u0026lt;=600 Ohms;\u003cbr\u003e1 Ohm \u0026lt;=6000 Ohms;\u003cbr\u003e10 Ohms \u0026lt;=60 kOhms\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% + 5 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000 uF\u003c\/td\u003e\n\u003ctd\u003e0.1 uF \u0026lt;=100 uF;\u003cbr\u003e1 uF \u0026lt;=1000 uF\u003c\/td\u003e\n\u003ctd\u003e+\/-(1% + 4 digits)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage between any terminal and earth ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 AA alkaline batteries, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C (14 deg F to +122 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C (-40 deg F to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-condensing below 10 deg C; \u0026lt;=90% RH at 10 deg C to 30 deg C; \u0026lt;=75% RH at 30 deg C to 40 deg C; \u0026lt;=45% RH at 40 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \/ storage altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m operating; 12000 m storage\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.9 cm x 8.5 cm x 4.5 cm (9.8 in x 3.3 in x 1.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e395 g (13.9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1020 g from local package data\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 mm (1.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible current probe diameter \/ cable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 mm diameter; 1.8 m cable length from head to electronics connector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 Pollution Degree 2; IEC 61010-2-032 CAT III 1000 V \/ CAT IV 600 V; IEC 61010-2-033 CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio frequency certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC ID:T68-FBLE; IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1 portable electromagnetic environment; IEC 61326-2-2; CISPR 11 Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTroubleshoot AC\/DC electrical systems in commercial and industrial environments\u003c\/li\u003e\n  \u003cli\u003eMeasure high current with the included iFlex flexible current probe\u003c\/li\u003e\n  \u003cli\u003eCheck variable frequency drive output using the VFD low-pass filter\u003c\/li\u003e\n  \u003cli\u003eCapture inrush current during motor startup and service checks\u003c\/li\u003e\n  \u003cli\u003eLog and share readings through Fluke Connect workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIncluded\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e18-inch iFlex Flexible Current Probe\u003c\/li\u003e\n  \u003cli\u003eTPAK Magnetic Hanging Strap\u003c\/li\u003e\n  \u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n  \u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n  \u003cli\u003eTwo AA alkaline batteries\u003c\/li\u003e\n  \u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n  \u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eManual\u003c\/h5\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.fluke.com\/c0b03278-b15d-450b-a2df-b10800c1ae82_original%20file.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFluke 374 FC \/ 375 FC \/ 376 FC User Manual\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.fluke.com\/c726ea70-724a-4147-8e53-b1060068b51a_original%20file.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFluke 370 FC Series Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44447794659524,"sku":"STINF-CM-0005","price":424.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/2636\/8196\/files\/fluke-376-clamp-meter-front-view.jpg?v=1778124809","url":"https:\/\/testinglab.shop\/products\/fluke-376","provider":"TestingLab.shop","version":"1.0","type":"link"}